Error Log Entries and Test to Clear Values

Table 175. DS1 Interface Media Module Maintenance Error Log Entries  
Error Type
Aux Data
Associated Test
Alarm Level
On/Off Board
Test to Clear Value
0*
0
Any
Any
Any
test board GGGVSpp
1(a)
0
Media module removed or SAKI Test (#53)
MIN/WRN**
ON
18(b)
0
busyout board GGGVSpp
WARNING
OFF
release board GGGVSpp
23(c)
0
WARNING
OFF
add ds1 GGGVSpp
125(d)
none 3
None
MIN/WRN**
ON
257
65535
Control Channel Loop Test (#52)
MINOR
ON
test board GGGVSpp l r 20
257(e)
Any
None
513(f)
Any
MIN/WRN**
ON
514(g)
46086
MIN/WRN**
ON
769(h)
46085
MIN/WRN**
ON
770(i)
46096
MIN/WRN**
ON
1281
Any
Loss of Signal Alarm Inquiry Test (#138)
MIN/WRN**
OFF
test board GGGVSpp
1320
Any
Loss of Signal Alarm Inquiry Test (#138)
MIN/WRN**
OFF
test board GGGVSpp
1321
Any
Loss of Signal Alarm Inquiry Test (#138)
MIN/WRN**
OFF
test board GGGVSpp
1322
Any
Loss of Signal Alarm Inquiry Test (#138)
MINOR
ON
test board GGGVSpp
1323
Any
Loss of Signal Alarm Inquiry Test (#138)
MIN/WRN**
OFF
test board GGGVSpp
1324
Any
Loss of Signal Alarm Inquiry Test (#138)
WARNING
OFF
test board GGGVSpp
1400, 1401(j)
Any
Loss of Signal Alarm Inquiry Test (#138) and Echo Cancellation Test (#1420)
MINOR
ON
test board GGGVSpp
1537(k)
46082
MIN/WRN**
ON
1538(l)
Any
MIN/WRN**
ON
1793
Any
Blue Alarm Inquiry Test (#139)
MAJ/MIN /WRN ***
OFF
test board GGGVSpp
1794
Any
Blue Alarm Inquiry Test (#139)
MAJ/MIN /WRN***
OFF
test board GGGVSpp
1795
Any
Blue Alarm Inquiry Test (#139)
MAJ/MIN /WNG***
OFF
test board GGGVSpp
2049
Any
Red Alarm Inquiry Test (#140)
MIN/WRN**
OFF
test board GGGVSpp
2305
Any
Yellow Alarm Inquiry Test (#141)
MIN/WRN**
OFF
test board GGGVSpp
2306
Any
Yellow Alarm Inquiry Test (#141)
MIN/WRN**
OFF
test Board GGGVSpp
2561
Any
Major Alarm Inquiry Test (#142)
MIN/WRN**
OFF
test board GGGVSpp
2817
Minor Alarm Inquiry Test (#143)
MIN/WRN**
OFF
test board GGGVSpp
3073 to 3160 (m)
Any
Slip Alarm Inquiry Test (#144)
MIN/WRN**
OFF
test board GGGVSpp r 6
3585 to 3601 (o)
Any
Misframe Alarm Inquiry Test (#145)
MIN/WRN**
OFF
test board GGGVSpp r 6
3840(p)
Any
None
3841(q)
4358
3842(r)
46097
3999(t)
Any
None
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures.
**If ports are assigned to the media module, then a minor alarm is raised. If no ports are assigned to the media module, then a warning alarm is raised. The alarm is raised after the media module has been missing for a period of 15 minutes. Warning alarms are also raised against any ports administered on the media module.
***Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options command.
Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the set options command.