Previous page Next page

The View Administrative Option

If you are using static addressing and encounter problems, use the following procedure to verify the current values of system parameters and file versions.

NOTE: Unless otherwise prevented using administration, the user can view but not change most of the parameters associated with Craft Local Procedures. For more information about this option, see the applicable user guide(s).

NOTE: If the View Network Information option is not available due to being disabled by administration, use the ADDR option to view IP Addresses. See Static Addressing Installation in Chapter 3: Local Administrative Options. The IP Addresses might have been entered incorrectly. Verify whether you were provided with correct IP Addresses.

  1. When you select VIEW from the Craft Local Procedure Screen, the following text displays:
Static Addressing screen

Line Description and (System Value)
Phone
Call Server
Router
Mask
File Server
802.1Q
VLAN ID
VLAN Test
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
NVL2Q text string
dddd
ddd

Telephone IP Address (IPADD)
Call Server in use; media server IP Address
Router in use; gateway/router Ip Address
IP network mask (NETMASK)
IP Address of HTTP/S File Server in use
NVL2Q setting text description
NVL2QVLAN
NVVLANTEST
  1. Use the Right and Left navigation arrows to scroll through the viewable information, shown in Table 2.
Table 2:  Parameter Values  
Name
System Value
Format
Phone
nnn.nnn.nnn.nnn
Telephone IP Address; IPADD value.
Call server
nnn.nnn.nnn.nnn
IP Address of the call server currently in use, otherwise “0.0.0.0.”
802.1X
If DOT1X = 0
If DOT1X = 1
If DOT1X = 2
Pass-thru mode.
Pass-thru with Logoff.
Supplicant mode.
Router
nnn.nnn.nnn.nnn
Up to 15 ASCII characters:
the IP Address of the router in use.
Mask
nnn.nnn.nnn.nnn
Up to 15 ASCII characters:
NETMASK value.
File server
nnn.nnn.nnn.nnn
IP Address of last file server used successfully during initialization or “0.0.0.0” if no file server was used successfully.
802.1Q
cccc
Text string corresponding to the NVL2Q value.
VLAN ID
cccc
Up to 4 ASCII characters. Value is L2QVLAN text "Auto" if 802.1Q tagging is 0 or "On" if 802.1Q tagging is 1. If 802.1Q tagging is off (2), this line is not displayed.
VLAN Test
ccc
Up to 3 ASCII characters. Value is VLANTEST value if 802.1Q tagging is 0 or 1. If 802.1Q tagging is off (2), this line is not displayed.
Ethernet

Text string corresponding to PHY1STAT value, for example, “auto,” “100Mbps HDX,” 1000Mbps FDX.”
PC Ethernet

Test string corresponding to PHY2STAT value, for example, “disabled,” “100Mbps HDX,” 1000Mbps FDX.”.
Model
96ccDccc
Up to 8 ASCII characters: MODEL serial number.
Phone SN
cccccccccccccccccc
Telephone Serial Number, up to 18 ASCII characters.
PWB SN
cccccccccccccccccc
Printed Wiring Board (circuit board) Serial Number, up to 18 ASCII characters. Applies only to 96xx IP Telephones that have a software-readable PWB serial number and comcode.
PWB comcode
nnnnnnnnn
9 ASCII numeric characters. Applies only to 96xx IP Telephones that have a software-readable PWB serial number and comcode.
MAC address
hh:hh:hh:hh:hh:hh
Each octet of the MAC address displays as a pair of hexadecimal numbers.
Group
nnn
Up to 3 ASCII numeric characters: GROUP value.
Protocol:

Application File “big app”
Ethernet

Boot file “little app”
cccccccc
filename.ext
cccccccc Ethernet

bootcodename
Up to 8 ASCII characters, currently only “H.323.”
4 to 32 ASCII characters (primary application).
2 to 8 ASCII characters, either"1000Mbps", “100Mbps”, “10Mbps”, or “No.”
1 to 32 ASCII characters (backup image name).
GigE Adapter
cccccccccccccc
14 ASCII characters. Version identifier of the GigE Adapter software, if applicable.
Button Module 1
cccccccccccccc
14 ASCII characters. Version identifier of the software in the first attached Button Module, if applicable.
Button Module 2
cccccccccccccc
14 ASCII characters. Version identifier of the software in the second attached Button Module, if applicable.
Button Module 3
cccccccccccccc
14 ASCII characters. Version identifier of the software in the third attached Button Module, if applicable.
  1. Press Back at any time to return to the Craft Local Procedure screen.

Previous page Next page